Shandong, CN · 00:00 GMT+8
Engineered in China · Delivered to 20+ markets
Industrial / 01 Single category brief

Frames for production that cannot stop.

A factory building is defined by what it has to carry: crane duty, equipment loads, clear height and the way material moves between bays. We start with those constraints, then engineer the frame, connections and envelope around them.

  • ISO 9001 / 14001 / 45001
  • AISC · EN · AS/NZS design
  • Engineer reply in 1 business day
Industrial Steel Structures
Crane-readyDuty-class design
Clear spanEngineered to project
100,000 tAnnual output
Fast brief / no obligation

Get a tonnage and budget range.

Three details are enough to start. An engineer reviews the brief and replies within one business day.

No newsletters. Your brief stays with the engineering team.

The brief

What this building has to get right.

Industrial steel structures are not a single product. A light assembly hall, a crane-served heavy workshop and a 60-metre clear-span production bay behave differently under load, wind and daily operation. Treating them as one catalogue item is how projects end up with an oversized frame in one area and an undersized one in another.

SDKM works from the process layout outward. Crane rails, mezzanine loads, openings, roof access and future expansion are coordinated before member sizes are fixed, so the steel package supports the operation rather than constraining it.

01 / Typical configurations

One category. Several ways to solve it.

A category is a brief, not a fixed catalogue item. These are the configurations we engineer most often; the final frame follows your span, loads and site.

Portal Frame Workshop 01
Clear span Fast erection Extendable

Portal Frame Workshop

Rigid goalpost frames span the full width without internal columns. Efficient, quick to erect and easy to extend bay by bay — the default choice for manufacturing, assembly and storage.

Heavy-Duty Crane Workshop 02
Crane beams Heavy plate Tall bays

Heavy-Duty Crane Workshop

Built-up plate girders, box columns and crane beams sized together for the real duty class. Bracket positions, wheel loads and braking forces are resolved before fabrication, not added after the frame is fixed.

Large-Span Roof System 03
Column-free Truss Space frame

Large-Span Roof System

When the middle has to stay open, the roof system carries the decision: steel truss, space frame or long-span portal. Geometry, deflection and transport limits are balanced before the package is split for shipping.

02 / Engineering envelope

The parameters we need before sizing steel.

None of these are catalogue defaults. Each one is agreed from the project brief, then fixed in the design basis and connection drawings.

Send your parameters
Structural systemPortal frame / heavy portal / truss or space frame
Clear spanEngineered to the project layout
Eave heightSet by equipment and lifting envelope
CraneOptional; designed to the declared duty class
RoofStanding seam, insulated panel or steel deck
Floor loadingCoordinated with slab and equipment loads
Design codesAISC / EN / AS-NZS / SNI / PNS
Have the numbers? Send span, height and site location. We return a tonnage range, not a brochure.
03 / Where it fits

Applications this system is built around.

The same frame family can serve very different operations. The layout and envelope change; the engineering discipline does not.

01Manufacturing workshop
02Assembly hall
03Crane bay
04Heavy equipment hall
05Process plant
06Service and maintenance building
04 / Delivery scope

One package, from design basis to erection sequence.

The scope is agreed before fabrication. Nothing is cut until the drawings, coatings, packing plan and site sequence are aligned.

STEP / 01

Design basis

Loads, spans, code, crane duty, racking or temperature range are fixed and reviewed with your engineer.

STEP / 02

Detailing

Shop drawings, connection details, bolt lists and erection sequence are issued before steel is cut.

STEP / 03

Fabrication

CNC cutting, fit-up, welding and trial assembly, with hold-point inspection records.

STEP / 04

Protection & packing

Surface preparation, coating system, bundle marks and export packing planned against the site sequence.

STEP / 05

Site support

Erection drawings, marked assemblies and remote or on-site guidance for the bolt-up phase.

Included in the steel package
  • Primary frame, purlins and bracing
  • Connections, anchor bolts and base plates
  • Shop drawings, bolt lists and erection sequence
  • Mill certificates and coating records
  • Marked export bundles and packing list
Quoted separately / by others
  • Foundations, slab and civil works
  • Erection labour and site equipment
  • Permits, inspections and local compliance
  • Freight, insurance and import duties

Final split is fixed in the offer, before fabrication.

05 / Built examples

The system, delivered on a real site.

All project deliveries
06 / Procurement notes

Questions buyers ask before releasing steel.

If your question is not here, send it with the project brief. We answer with the engineering reason, not a sales line.

Can the building be extended later?

Yes. Bays can be added on the long side or at the end, provided the original bracing and foundation assumptions are documented. We keep the extension path in the design brief so a future bay does not force a rebuild.

How is crane duty handled?

The crane class, wheel loads, hook approach and braking forces are declared at the start. Crane beams, brackets and column sizes are then designed as one system. A crane allowance added after member sizes are fixed usually costs more than designing it in.

Do you design to our local code?

We detail to the governing code agreed in the brief — AISC, Eurocode, AS/NZS, SNI or PNS — and issue the design basis, load combinations and connection assumptions for your engineer to review.

What is included in the export package?

Fabricated primary and secondary members, connections, bracing, anchor bolts, marked bundles, mill certificates, coating records and an erection sequence. Envelope and installation labour are scoped separately unless requested.

Question not covered? Send it with the brief or WhatsApp an engineer.

07 / Start this brief

Send the constraint.
We engineer the rest.

Span, load, temperature, site access, code, timeline — whatever is fixed. An engineer reviews it and comes back with the questions that matter and a route to quotation.

  • 01
    Budget rangeUS$/m² band for your span, height and duty.
  • 02
    Tonnage estimatePrimary, secondary and coating allowance.
  • 03
    Engineering questionsThe few items we need before design freeze.
Industrial Steel Structures project brief Reply within 1 business day

Your brief is used only to respond to this project. No lists, no resale.

SDKM certificate

Certificate